Two of most accurate and commonly used temperature sensors are RTD & Thermocouple.Thermowells are tubular fittings used to protect temperature sensors installed in industrial processes. 

 - - - - - - - - - +
X
010
Model
 
 
 Product description
Temperature Sensor
X
020
Head Material
 
 
  
Aluminum
Stainless Steel 316
Without Head
X
030
Connection Head
 
 
  Conduit threadProcess Thread
No Additional Enclosure
Universal Connection Head with 1 Elec. Entry/IP65 M20 x 1.5M20 x 1.5
Explosion Proof Connection Head with 1 Elec. Entries/IP67 M20 x 1.5M20 x 1.5
Remote HeadM20 x 1.5M20 x 1.5
X
040
Sensor lead wire termination
 
 
  Details
Flying Lead No Springs on DIN plate
Terminal BlockWith Spring on DIN 43762
Spring loaded No Plate with spring loaded Process Connection Adaptor
X
050
Sensor type
 
 
  
RTD, PT-100, Single Element, 2 Wires, Thin Film, Class AA (0..150°C) , Class A (-30..300 °C), Class B(-50..500°C)
RTD, PT-100, Single Element, 3 Wires, Thin Film, Class AA (0..150°C) , Class A (-30..300 °C), Class B(-50..500°C)
RTD, PT-100, Single Element, 4 Wires, Thin Film, Class AA (0..150°C) , Class A (-30..300 °C), Class B(-50..500°C)
RTD, PT-100, Dual Element, 2 Wires, Thin Film, Class AA (0..150°C) , Class A (-30..300 °C), Class B(-50..500°C)
RTD, PT-100, Dual Element, 3 Wires, Thin Film, 4 Wires Termination Class AA (0..150°C) , Class A (-30..300 °C), Class B(-50..500°C)
RTD, PT-100, Single Element, 2 Wires, Wire Wound, Class AA (-50..250 °C), Class A (-100..450 °C), Class B (-196..600°C)
RTD, PT-100, Single Element, 3 Wires, Wire Wound, Class AA (-50..250 °C), Class A (-100..450 °C), Class B (-196..600°C)
RTD, PT-100, Single Element, 4 Wires, Wire Wound, Class AA (-50..250 °C), Class A (-100..450 °C), Class B (-196..600°C)
RTD, PT-100, Dual Element, 3 Wires, Thin Film, 6 wires Termination, Class AA (0..150°C) , Class A (-30..300 °C), Class B(-50..500°C)
Thermocouple , Type E Single Element, Ungrounded, Class 1, -40 to 800 °C
Thermocouple, Type E Dual Element, Isolated, Ungrounded, Class 1, -40 to 800 °C
Thermocouple, Type K, Single Element, Ungrounded, Class 1, -40 to 1000 °C
Thermocouple, Type K Dual Element, Isolated, Ungrounded, Class 1, -40 to 1000 °C
Thermocouple, Type J, Single Element, Ungrounded, Class 1, -40 to 750 °C
Thermocouple, Type J Dual Element, Isolated, Ungrounded, Class 1, -40 to 750 °C
Thermocouple, Type T, Single Element, Ungrounded, Class 1, -40 to 350 °C
Thermocouple, Type T Dual Element, Isolated, Ungrounded, Class 1, -40 to 350 °C
Thermocouple, Type N Single Element, Isolated, Ungrounded, Class 1, -40 to 350 °C
Thermocouple, Type N Dual Element, Isolated, Ungrounded, Class 1, -40 to 350 °C
Thermocouple, Type R, Single Element, Ungrounded, Class 1, 0 to 1000 °C
Thermocouple, Type R Dual Element, Isolated, Ungrounded, Class 1, 0 to 1000 °C
Thermocouple, Type S, Single Element, Ungrounded, Class 1, 0 to 1000 °C
Thermocouple, Type S Dual Element, Isolated, Ungrounded, Class 1, 0 to 1000 °C
Special Item
X
060
Sensor Diameter
 
 
  
3 mm
5 mm
6 mm
6.3 mm
8 mm
10 mm
X
070
Dimension Unit
 
 
  Details
Metric units (mm)Only applies to lengths
English/U.S. units (inches)
X
080
Sensor immersion Length
 
 
   Details
xxxx mm50 to 2000 mm in 5-mm increments (when ordered with Dimension units code M)Example of a 50 mm length: 0050
xxx.x inches2 to 80 inches in ¼ inches increments (when ordered with Dimension units code E)Example of a 6.25-in. length where the second decimal is dropped off: 0062
X
090
Process Connection
 
 
  
No Additional Fitting (The selected connection head will determine process connection)
½-14 NPT Male
G ½ (BSPP) Male
¼-18 NPT Male
G ¼ (BSPP) Male
1/8-27 NPT Male
G 1/8 (BSPP) Male
Other
X
100
Extensions
 
 
  Details
No Coupling, Nipple and Union
Coupling Adaptor, length: yyy mmyyy refers to the Length of Coupling Extension must be greater than 65mm
Coupling Nipple-Union Adaptor, length: yyy mmyyy refers to the Length of Coupling Extension must be greater than 83mm
One Nipple, length: xxx mmxxx refers to the length of Nipple. e.g. Y050-N000 means one nipple with 50mm length.
X
110
More Options
 
 
  
Wire color per ISA
Wire color per IEC
Assemble sensor to specific temperature transmitter (PVC Tube for Sensor Protection)
External ground screw
SST tag Plate, Includes Serial No., Customer Tag No. & Sensor Calibration Range Dimension: 3.5 x 6 Cm, Thickness 1 mm
Compress Fitting Adjustable
ATEX II 2G Exd IIC T6 Gb Explosion Proof